ClairHydra RO Series reverse osmosis system

RO Series

Reverse osmosis systems engineered to your site's feed-water TDS and hardness — not a generic off-the-shelf unit.

Book Your Free Site Assessment

Why ClairHydra RO

Engineered Around Your Site's Water, Not a Shelf Spec

Sized to Your Site's Water

Every RO system is specified against your site's actual feed-water TDS, hardness, and duty cycle before a quotation is issued — not picked off a shelf.

High-Recovery Engineering

Up to 60% recovery* — more purified water delivered per liter of feed, less sent to drain.

Consistent Permeate Quality

Up to 98% salt rejection*, holding permeate TDS below 150 PPM across the RO Series.

Scales With Demand

Five models from 125 up to 1000 LPH*, sized to match your site's peak draw.

*"Up to" values represent maximum theoretical capacity under ideal test conditions — applies to flow rate, salt rejection, recovery. Salt rejection applies across the RO Series (CH125RO–CH1000RO); the 60% recovery figure applies to CH250RO–CH1000RO (CH125RO's maximum recovery is 50%); 1000 LPH is the CH1000RO model's rated output.

0%

Salt Rejection*

0%

Recovery Rate*

0 LPH

RO Output*

*"Up to" values represent maximum theoretical capacity under ideal test conditions — applies to flow rate, salt rejection, recovery. Salt rejection applies across the RO Series (CH125RO–CH1000RO); the 60% recovery figure applies to CH250RO–CH1000RO (CH125RO's maximum recovery is 50%); 1000 LPH is the CH1000RO model's rated output.

Technical Specifications

RO Series, Model by Model

Every figure below is copied directly from the verified RO Series spec sheet — nothing rounded, nothing estimated.

View Full Technical Specifications
Model Flow Rate Max Input TDS Max Input Hardness Permeate TDS Salt Rejection Recovery Duty Cycle
CH125RO 125 LPH* up to 3000 PPM† 1000 PPM <150 PPM up to 98%* up to 50%* up to 6 hours‡
CH250RO 250 LPH* up to 2000 PPM† 1000 PPM <150 PPM up to 98%* up to 60%* up to 6 hours‡
CH500RO 500 LPH* up to 2000 PPM† 1000 PPM <150 PPM up to 98%* up to 60%* up to 6 hours‡
CH750RO 750 LPH* up to 2000 PPM† 1000 PPM <150 PPM up to 98%* up to 60%* up to 6 hours‡
CH1000RO 1000 LPH* up to 2000 PPM† 1000 PPM <150 PPM up to 98%* up to 60%* up to 6 hours‡

*"Up to" values represent maximum theoretical capacity under ideal test conditions — applies to flow rate, salt rejection, recovery. Salt rejection applies across the RO Series (CH125RO–CH1000RO); the 60% recovery figure applies to CH250RO–CH1000RO (CH125RO's maximum recovery is 50%); 1000 LPH is the CH1000RO model's rated output.

†Pre-treatment (Auto Sand Filter) is mandatory above stated TDS/hardness/turbidity thresholds to achieve stated performance.

‡Continuous supply/uptime claims assume adherence to recommended duty cycle and maintenance schedule.